Título: Cálculo análise da carga térmica das salas de aula do bloco A do Instituto Federal do Piauí - campus Teresina Central
Autor: Caldas, Daniele dos Santos Viana
Orientador(a): Fortes, Anderson Felipe Chaves
metadata.dc.contributor.referee1: Pereira Filho, Edivaldo Feitosa
metadata.dc.contributor.referee2: Serra, Petteson Linniker Carvalho
Resumo: O projeto de climatização é uma atividade essencial para garantir o conforto térmico e a eficiência energética de um ambiente. A crescente demanda por energia, tanto no Brasil quanto no mundo, torna esse projeto ainda mais importante, pois pode ajudar a reduzir o consumo de energia e, consequentemente, os custos operacionais. Além disso, estudos apontam que o conforto térmico está diretamente ligado à produtividade do indivíduo. Em um ambiente climatizado adequadamente, as pessoas se sentem mais confortáveis e, consequentemente, mais dispostas a trabalhar ou realizar atividades cotidianas. A fim de garantir o conforto térmico dos ocupantes das salas de aula do prédio A do IFPI - Campus Teresina Central, foi realizado um estudo para dimensionar as parcelas de carga térmica desses ambientes, para isso, foi utilizada a metodologia ASHRAE CLTD/SCL/CLF e norma ABNT NBR 16401, e como meio de validar os valores encontrados foi feito a simulação da carga térmica desses ambientes no Software HAP, os resultados encontrados foram bem próximos, obtendo sucesso na validação. Os resultados do estudo mostraram que a carga térmica total das salas de aula é de 750 kBtu/h, a maior parcela dessa carga é devida à renovação de ar, representando cerca de 32% do total. Isso ocorre porque as salas de aula são ambientes fechados, onde o ar quente e úmido se acumula, causando desconforto térmico. A segunda maior parcela da carga térmica é devida às superfícies opacas, representando cerca de 27% do total. As superfícies opacas como paredes e tetos, absorvem o calor do ambiente interno e o devolvem posteriormente. As demais parcelas da carga térmica são devidas às pessoas, aos equipamentos e à infiltração de ar pelas frestas das portas e janelas. Para atender à demanda térmica encontrada, foi recomendado o uso de 18 aparelhos de ar-condicionado, sendo cinco com 60.000 Btu/h, quatro com 56.000 Btu/h, dois com 37.000 Btu/h, quatro com 24.000 Btu/h, um com 40.000 Btu/h, um com 18.000 Btu/h e um com 23.000 Btu/h. As recomendações apresentadas visam garantir o conforto térmico dos ocupantes das salas de aula do prédio A do IFPI - Campus Teresina Central, proporcionando um ambiente adequado para a realização de atividades acadêmicas e profissionais.
Abstract: Air conditioning design is an essential activity to ensure thermal comfort and energy efficiency in a space. The growing demand for energy, both in Brazil and around the world, makes this project even more important, as it can help to reduce energy consumption and, consequently, operating costs. In addition, studies show that thermal comfort is directly linked to individual productivity. In a properly air-conditioned space, people feel more comfortable and, consequently, more motivated to work or carry out daily activities. In order to ensure the thermal comfort of the occupants of the classrooms in the A building of the IFPI - Teresina Central Campus, a study was carried out to dimension the thermal load fractions of these environments. For this, the ASHRAE CLTD/SCL/CLF methodology and ABNT NBR 16401 standard were used. As a way to validate the values found, the thermal load simulation of these environments was carried out in the HAP Software. The results found were very close, achieving success in the validation. The results of the study showed that the total thermal load of the classrooms is 750 kBtu/h. The largest portion of this load is due to air renewal, representing about 32% of the total. This occurs because classrooms are closed environments where hot and humid air accumulates, causing thermal discomfort. The second largest portion of the thermal load is due to opaque surfaces, representing about 27% of the total. Opaque surfaces, such as walls, ceilings, and floors, absorb heat from the internal environment and return it later. The remaining portions of the thermal load are due to people, equipment, and air infiltration through the cracks in doors and windows. To meet the thermal demand found, the use of 18 air conditioners was recommended, with five with 60,000 Btu/h, four with 56,000 Btu/h, two with 37,000 Btu/h, four with 24,000 Btu/h, one with 40,000 Btu/h, one with 18,000 Btu/h, and one with 23,000 Btu/h. The recommendations presented aim to ensure the thermal comfort of the occupants of the classrooms in the A building of the IFPI - Teresina Central Campus, providing an appropriate environment for the conduct of academic and professional activities.
Palavras-chave: Carga térmica
Conforto térmico
Climatização
Cnpq: CNPQ::ENGENHARIAS
metadata.dc.language: por
País: Brasil
Editor: Instituto Federal de Educação, Ciência e Tecnologia do Piauí
Sigla: IFPI
Unidade: Campus Teresina Central
Citação: CALDAS, Daniele dos Santos Viana. Cálculo e análise da carga térmica das salas de aula do Bloco A do Instituto Federal do Piauí do Brasil - Campus Teresina Central. Orientador: Anderson Felipe Chaves Fortes. 2023. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Mecânica) - Instituto Federal de Educação, Ciência e Tecnologia do Piauí, Campus Teresina Central, 2023.
Tipo de acesso: Acesso Aberto
URI: https://bia.ifpi.edu.br/jspui/handle/123456789/2543
Data do documento: 2023
Aparece nas coleções:Bacharelado em Engenharia Mecânica - Teresina Central

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2023_tcc_dsvcaldas.pdf9.71 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.